This table describes coating systems for FPU products. It is indended for guideline purpose. Prior to implementing the specifications of a particular system, please contact the manufacturer or nearest representative for final evaluation. Example of recognized Associations: NACE, SSPC and Concrete Institute of America . Important to specify if VOC requirement is 2.8 or 3.5. FPUWC series color pigment are in compliance with US Federal specifications 595B and Australian color standards. Warranties are issued on a project to project basis and vary from one application to another. It is the duty of the Engineering firm and or the contractor to contact the manufacturer for specific details, prior to issuing or making any claim of warranty.
Description | Short Form Specs | Application |
---|---|---|
System: 101 Interior coating for fule (POL) tanks |
Interior, Steel
| |
System 102 Interior Coating for Concrete tanks (Fuel, Sewer Treatment, etc.) |
|
Interior, Concrete
|
System 103 Interior of Concrete Potable-Water Tanks ICPW AS4020 (Australian Certified) |
|
Interior, Concrete, Potable Water
|
System 104 AS4020 (Australian Standard) |
|
Interior, Steel, Potable Water
|
System 105 (US Navy Specs) |
Please refer to the US Navy NGFS 09970 (for use on Navy projects.) NFGS Modified FPUWC5Ô |
Interior, Steel This specs is for interior coating for welded steel tanks(POL). |
System 106S Anti-Graffiti protection for steel surfaces. |
Exterior, Steel, Anti Graffiti
|
|
System 106C Anti-Graffiti protection for concrete surfaces. |
Exterior, Concrete, Anti Graffiti
|
|
System 107 Weather Protection of Exterior Steel Surfaces |
Excellent UV and Salt resistance
(available in colours and clear) Note: Due to the diversified areas of application, please consult with the manufacturer prior to implementing the suggested specs. Some primers and intermediate coats may vary according to the areas of application. For hot and humid tropical geographic areas different types of modified epoxies may be required. While this system may be used as a coating on the bottom of speed boat hulls for reducing drag, it is not intended for use as a fouling release system |
Exterior, Steel
|
System 108 Steel Splash Zone |
Note: Due to the diversified areas of application, please consult with the manufacturer prior to implementing the suggested specs. Some primers and intermediate coats may vary according to the areas of application. For hot and humid tropical geographic areas different types of modified epoxies may be required. While this system may be used as a coating on the bottom of speed boat hulls for reducing drag, it is not intended for use as a fouling release system |
Steel, Splash Zone
|
System 109 Concrete Splash Zone 21CC-FPUWC15Ô |
Refer to system 103. Potable water certification not required, unless otherwise specified |
Concrete, Splash Zone
|
System 110 External Steel surfaces requiring protection from heat. |
Refer to System 107, but substitute 21CC-FPUWC15 for added protection from heat or solar reflection on tank vessels or exterior of heat exchangers. |
Exterior, Steel, Underground
|
System 111C Non-Skid Surface for Concrete Floors |
|
Exterior, Concrete
|
System 111S Non-Skid Surface for Steel Floors |
|
Exterior, Steel
|
System 111W Non-Skid Surface for Wood Deck |
|
Exterior, Wood
|
System 111MW Non-Skid Surface for Marine Wood Deck |
Refer to System 111W. Substitute FPUWC-15 (NS) for extra protection against extreme weather. |
Exterior, Wood
|
System 111MS Non-Skid Surface for Marine Steel Deck |
Refer to System 111S. Substitute FPUWC-15 (NS) for extra protection against extreme weather, especially in mechanical areas on offshore platforms. |
Exterior, Steel
|